Anton Paar Multiwave Go User Manual

This level of detail makes it easy to find areas where fish like to hide, like drop-offs, points, and ditches. Lowrance elite 4 chirp user manual instructions. A truly customizable mapping experience, Genesis Live gives you control over contour transparency, contour density, depth and safety shading color palettes, and more. Update the maps of your favorite fishing spot or map unmapped areas with ½ foot contours – in real time – on the screen of your fishfinder/chartplotter with C-MAP Genesis Live. Genesis Live uses digital depth to create high-definition maps featuring 1/2-foot contours.

Digesters from Anton Paar. Microwave Reaction System - Multiwave PRO. Get More Info. User Interface Options. User Interface Display Type. Ultimate Digestion System - HPA-S. Anton Paar Microwave Digestion System - Multiwave GO. Anton Paar Microwave Reaction System - Multiwave PRO. Anton Paar STAY CONNECTED WITH US. The Anton Paar Multiwave system has set the standard for modern microwave-assis-ted sample preparation. Due to its safe and easy handling, its reliable operation and excellent analytical results, it plays a key role in hundreds of laboratories all over the world. However, now is the time for the next step in innovation! Making good things better. Multiwave PRO as a platform system allows digestion, leaching, oxygen combustion, solvent extraction, drying, evaporation, and UV digestion with one single system. Anton Paar's 90 years of experience in smart engineering and consistent use of high-quality components result in a microwave reaction system which runs reliably for years. Opening and sealing Multiwave PRO’s rotors, vessels and sensors is quick and simple - just use your hands. This tool-free handling is unique to Anton Paar and simplifies this frequently repeated work step.

Anton Paar Multiwave Go User Manual Pdf

The world’s smallest and most economic microwave for digestion

Anton Paar GmbH - Multiwave 3000 (Microwave digestion system) Year of introduction: Status: historical ( out of sale ) Company: Anton Paar GmbH: Categories: Microwave apparatus: Digester: Combining the benefits of a closed-vessel system with rapid microwave heating, Multiwave 3000 is a highly modular and therefore very versatile system which. The goal of microwave digesters is to completely break down samples such as metals, pharmaceuticals, plants, soil, or food so they are ready for elemental analysis.

The Multiwave GO Plus microwave digestion system with the patented Directed Multimode Cavity (DMC) provides the best of both monomode and multimode microwaves. The microwave field adapts itself to the number of filled or empty positions and the filling state of the vessel – that’s truly innovative. Due to the TURBO cooling process, unique cooling times as short as eight minutes for a fully loaded twelve-position rotor are possible (for EPA methods). With its SmartVent technology, Multiwave GO Plus is the most convenient microwave digestion system on the market.

Get in touch Document Finder

GO for TURBO concept – the shortest process times on the smallest footprint

The unique Directed Multimode Cavity (DMC) of Multiwave GO Plus enables highly efficient TURBO heating with only one magnetron in a compact system. As in a monomode system, the microwaves are directed to the sample, providing highly efficient heating in a small-footprint system. As in a multimode system, more than one sample can be digested in a single run.

In combination with the most effective TURBO cooling system for rapid cooling from 180 °C to 70 °C in less than eight minutes (for EPA methods) Multiwave GO Plus provides you with the shortest overall process times on the market. This is possible due to the perfect interplay between the built-in cooling unit, exhaust, rotor, and vessels (with cooling fins) and also makes the smallest footprint become a reality.

GO for SmartVent – the easiest way of reaction control

The innovative SmartVent technology uses the pressure-activated-venting concept of Anton Paar which ensures excellent digestion quality. The three-part vessels are HF-resistant and are closed without tools.

John deere 650 shop manual download. This highly detailed John Deere 650 Tractor Repair Manual is very useful and contains everything you need to repair your John Deere. All our manuals come with a 100% Money Back Guarantee! Models Covered: 650 Manuals Included: TM-1242 Total Pages: 794 Manual Sections. John Deere 650 Tractor Service Manual John Deere 650 Tractor Technical Manual TM1242 796 Pages in.pdf format 186.5 MB in.zip format for super fast downloads! This factory John Deere Service Manual Download will give you complete step-by-step information on repair, servicing, and preventative maintenance for your John Deere. The John Deere. JOHN DEERE 650 WORKSHOP SERVICE REPAIR MANUAL This manual contains information and data to this model. Has specs, diagrams, and actual real photo illustrations. These technical manual is as good as it gets for Diagnosing, Repairing, and Maintaining John Deere machinery. In addition to space savings, nice thing about having PDF files instead of a.

With the SmartVent technology you GO for:

Anton Paar Multiwave Go

  • precise pressure control in each vessel
  • releasing overpressure safely
  • detecting increased digestion temperatures
  • extremely high sample weights
  • safely digesting samples with different, unknown reaction behavior in the same run

Multiwave GO Plus – goes easy for a huge variety of samples

A huge variety of samples can be reliably digested with Multiwave GO Plus. These include environmental samples, food and feed analysis, material testing, as well as petrochemical, plastic, polymer, cosmetic, metal, alloy, and geochemical samples.

A multitude of samples can be easily digested with preinstalled generic methods (e.g. EPA 3015A, EPA 3051A, or EPA 3052) which further simplifies your workflow.

Benefit from a complete microwave system in a compact design with which you can perform routine digestion and leaching of high sample amounts, low sample amounts, inorganic or organic matrices.

Anton Paar Certified Service

The Anton Paar quality in service and support:
  • More than 350 manufacturer-certified technical experts worldwide
  • Qualified support in your local language
  • Protection for your investment throughout its lifecycle
PaarLearn more

Anton Paar Multiwave Go Specifications

  • Acid Leaching of Environmental Samples in Multiwave GO / GO PlusApplication Reports en
  • Beverage Soft Drinks Complete Your Soft Drink AnalysisApplication Reports en
  • Complete Recovery of Mercury in Fly Ash with Multiwave GO / GO PlusApplication Reports en
  • Digestion of Food and Other Organic Samples in Multiwave GO / GO PlusApplication Reports en
  • Lowest Blanks Over Long Time of UsageApplication Reports en
  • Microwave-assisted Acid Digestion of Cannabis Products with Pressure-activate VentingApplication Reports en
  • Total Digestion with HF in HVT Vessels and Complexation of Fluoride with Saturated Boric AcidApplication Reports en