Nov 20, 2018  The Fluke 87 True RMS Multimeter (also referred to as 'the meter') is a handheld, 4000-count instrument that is designed for use in the field, laboratory, and at home. The meter combines the precision of a digital meter with the speed and versatility of a high resolution analog display. The Fluke 87V True-RMS Industrial Digital Multimeter with Temperature Measurement is the right choice, when productivity is on the line and you need to solve problems fast. The 87-5 instrument delivers the accuracy and advanced troubleshooting capabilities you need.

  1. Fluke 87 Iii Manual
  2. Fluke 87 Multimeter User Manual
  3. What Is A True Rms Multimeter

Page 29: Cat ii, Min max range hold h hz rel, 4 1/2 digits 1 seconds, True rms multimeter, Figure 6. testing a diode, Typical reading, Forward bias reverse bias

This manual contains information and warnings which must be followed to ensure safe operation and retain the meter in safe condition. If the meter is not used as described in this manual, the safety features of the meter might be impaired. Warning Read 'Multimeter Safety' before using the meter. The Fluke 87 True RMS Multimeter (also referred to as. Model 87 & 89 Series IV Users Manual 1-2 Table 1-1. Safety Information WWarning To avoid possible electric shock or personal injury, follow these guidelines:. Do not use the meter if it is damaged. Before you use the meter, inspect the case. Look for cracks or missing plastic. Pay particular attention to the insulation surrounding the.

Advertising

Fluke 85-3 USA TRUE RMS Multimeter. TRUE RMS Multimeter. Introducing the new and improved Fluke 80 Series III digital multimeters The most versatile meters on the market just got better. Since their introduction, Fluke 80 Series digital multimeters (DMMs) have led the industry in versatile performance, accuracy, and rugged durability. Oct 02, 2018 Summary of Contents1 Fluke Multimeter User Manual2 Klein Multimeter User Manual3 Mastech Multimeter User Manual4 Craftsman Multimeter User Manual5 Amprobe AM-530 Multimeter User Manual6 Fieldpiece HS33 Multimeter User Manual7 Tacklife CM02A Multimeter User Manual8 UEi Test instruments DL369 Multimeter User Manual9 Extech EX330 Autoranging mini Multimeter User Manual10 Etekcity MSR-C600 digital.

Making Measurements

21

Testing Diodes

Caution

To avoid possible damage to the meter or to
the equipment under test, disconnect circuit
power and discharge all high-voltage
capacitors before testing diodes.

Use the diode test to check diodes, transistors, silicon
controlled rectifiers (SCRs), and other semiconductor
devices. This function tests a semiconductor junction by
sending a current through the junction, then measuring
the junction’s voltage drop. A good silicon junction drops
between 0.5 V and 0.8 V.

To test a diode out of a circuit, set up the meter as shown
in Figure 6. For forward-bias readings on any
semiconductor component, place the red test lead on the
component’s positive terminal and place the black lead
on the component’s negative terminal.

In a circuit, a good diode should still produce a forward-
bias reading of 0.5 V to 0.8 V; however, the reverse-bias
reading can vary depending on the resistance of other
pathways between the probe tips.

MIN MAX

RANGE

HOLD

H

Hz

REL

mA

A

mV

V

V

OFF

!

!

A

COM

V

mA

µ

A

1000V MAX

400mA MAX

FUSED

10A MAX

FUSED

PEAK MIN MAX

µ

A

CAT II

+1994 mercury topaz repair manual download pdf.

Typical
Reading

MIN MAX

RANGE

HOLD

H

Hz

REL

mA

A

mV

V

V

OFF

!

!

A

COM

V

mA

µ

A

1000V MAX

400mA MAX

FUSED

10A MAX

FUSED

PEAK MIN MAX

µ

A

CAT II

+

Forward Bias

Reverse Bias

4 1/2 DIGITS

1 Seconds

87

TRUE RMS MULTIMETER

III

4 1/2 DIGITS

1 Seconds

87

TRUE RMS MULTIMETER

III

iy9f.eps

Figure 6. Testing a Diode

Advertising
This manual is related to the following products:
Popular Brands
Popular manuals

Summary of Contents

Fluke Multimeter User Manual

Fluke ManualLinks
Fluke 115 Compact True-RMS digital multimeterDownload
Fluke 117 Electricians True RMS MultimeterDownload
Fluke 87-V digital multimeterDownload
Fluke 101 Basic digital best multimeter for electronics hobbyistDownload
Fluke 116/323 KIT HVAC Multimeter and clamp meter combo kitDownload
Fluke 323 True-RMS Clamp meterDownload
Fluke 77-IV automotive digital multimeterDownload

Klein Multimeter User Manual

Klein ManualLinks
Klein Tools CL800 digital clamp meterDownload
Klein Tools MM700 digital multimeterDownload
Klein Tools MM400 digital multimeterDownload
Klein Tools 69149 electrical test kitDownload
Klein Tool MM500 digital MultimeterDownload

Mastech Multimeter User Manual

Mastech ManualLinks
Mastech MS8268 Series digital multimeterDownload
Mastech MS8229 digital multimeterDownload
Mastech MS8264 digital multimeterDownload
Mastech MS2115A/B digital MultimeterDownload

Craftsman Multimeter User Manual

Craftsman ManualLinks
Craftsman 34-82141 digital multimeterDownload
Craftsman 34-82007 digital multimeterDownload
Craftsman digital multimeter with AC voltage detectorDownload

Amprobe AM-530 Multimeter User Manual

Amprobe AM-530 ManualLinks
Amprobe AM-530 TRMS electrical contractor multimeterDownload

Fieldpiece HS33 Multimeter User Manual

Fieldpiece HS33 ManualLinks
Fieldpiece HS33 multimeter for HVACDownload

Tacklife CM02A Multimeter User Manual

Tacklife CM02A ManualLinks
Tacklife CM02A autoranging multimeterDownload

UEi Test instruments DL369 Multimeter User Manual

UEi Test instruments DL369 ManualLinks
UEi Test instruments DL369 clamp on meterDownload

Extech EX330 Autoranging mini Multimeter User Manual

Fluke 87 Iii Manual

Extech EX330 ManualLinks
Extech EX330 Autoranging mini multimeterDownload

Fluke 87 Multimeter User Manual

Etekcity MSR-C600 digital clamp meter Multimeter User Manual

What Is A True Rms Multimeter

Etekcity MSR-C600 ManualLinks
Etekcity MSR-C600 digital clamp meter multimeterDownload